2‑1/2″ Hopper CW

2‑1/2" aluminum frame, in-swing window maximizes ventilation and light in high or low locations or small spaces
5200 series, Project In Hopper

Product Features

Standard

  • Windows are tested to AAMA standards
  • 1″ Insulated  glass
  • .062 aluminum wall thickness
  • Opens inward to maximize space
  • Typical commercial thermal ratings met with appropriate glass packages
  • Mulls with all 2 1/2″ frame depth operable and fixed windows
  • Factory assembled, common jamb mull upgrades structural integrity and accelerates installation
  • Structurally, thermally, and acoustically tested and certified

STANDARD HARDWARE

  • Brushed white bronze cam handle
  • Four bar hinges
  • Flat screen
  • Limit stops as necessary for opening restrictions

Optional

  • Internal(GBG), Interior, & Exterior Simulated Divided Lites (SDL)
  • Exterior applied in-frame profiled grids are widely approved for Historic applications
  • Dual and triple low-e configurations for increased thermal ratings
  • Available with equal leg frames, 1” new construction fin, & 1 1/2″ flange frames
  • Custom integral flange frames to meet unique installation conditions
  • Full range of tested and approved STC & OITC results for increased acoustic ratings
  • Operable blinds-between-the-glass reduce maintenance time and eliminate child cord hazards
  • Stainless mesh security screens

OPTIONAL HARDWARE

  • Removable maintenance handle with hardware cap
  • WOCD (re-engageable limit device)
  • NYC DOH approved limit stops
  • Trickle ventilators
  • Pole operable hardware
  • Dual locks

Product Summary

Hopper CWFrameTest SizeAAMA RatingWater psfU-Value RangeSHGC Range
Project-in Hopper2-1/2"4'0" x 2'8"CWPG406.0.48 - .65.52 - .26
Fixed Lite2-1/2"5'0" x 5'0"F-CW10012.0.28 - .56.66 - .21

Product Details

PRODUCT DATA


2‑1/2″ Hopper CW

Product Summary & Performance Data


Hopper CW
Project-in HopperFixed Lite
AAMA Rating
CWPG40
CW100
Test Size
4'0" x 2'8"5'0" x 5'0"
Frame Depth
2-1/2"
2-1/2"
Insulated Glass Thickness
1"
1"
Structural Load (psf)60150
STC Range30-3928-37
OITC Range24-3222-31

Series Drawings

Specifications